ePlaquette SmartDupline BUILDING Product - page 7

Building Automation
CARLO GAVAZZI Automation Components. Specifications are subject to change without notice. Illustrations are for example only.
18
Our product ra ge
RGC2A, RGC3A
• Product width 54 mm up to 70 mm,
DIN mount
• Rated operational voltage: up to 660
VAC
• Rated current: up to 75 AAC/pole
(RGC2A), 65 AAC/pole (RGC3A) @
40°C
• Control input: 5-32 VDC, 20-275 VAC
(24-190 VDC)
• CE - cULus
MAIN FEATURES
• Integrated output overvoltage protection
• Optional monitoring for SSR and load
circuit malfunction (RGC..M)
• 100 kA short circuit current rating
3-phase solid state
contactors
RJ1P
• Dimensions: 81.7 x 45 x 107 mm,
DIN mount
• Rated operational voltage: up to 660
VAC
• Rated current: up to 50 AAC @ 25°C
• Control input: 4-20 mA, 0-10 V
• CE - cURus
MAIN FEATURES
• Integrated heatsink
• Phase angle or Distributed full cycle
switching
• Optional ovetemperature protection
1-phase
proportional controllers
3-phase
proportional controllers
RGC2P, RGC3P
• Product width 54 mm up to 70 mm, DIN
mount
• Rated operational voltage: 180 - 660 VAC
• Rated current: up to 75 AAC/pole
(RGC2P), 65 AAC/pole (RGC3P) @
40°C
• Control input: 0-20 mA, 4-20 mA, 12-
20 mA, 0-10 V, 0-5 V, 1-5 V, external
potentiometer
• CE - cULus
MAIN FEATURES
• Integrated output overvoltage protection
• Phase angle, Distributed full cycle or Soft
start as switching modes
• Integrated monitoring for SSR and load
circuit malfunction
RGC1A
• Product width 17.5 mm up to 70 mm,
DIN mount
• Rated operational voltage: up to 660
VAC
• Rated current: up to 85 AAC @ 40°C
• Control input: 4-32 VDC, 20-275 VAC
(24-190 VDC)
• CE - cULus - VDE - GL (up to 30 AAC)
MAIN FEATURES
• Integrated heatsink
• 100 kA short circuit current rating
• Optional overtemperature protection
1-phase solid state
contactors
RSBD / RSBT
• Enhanced current reduction capability
with patented auto-adaptive algorithm
• Integrated
advanced
diagnostic
functions
• 2-phase (RSBD) and 3-phase (RSBT)
controlled and internally bypassed
solutions
• Top of ramp and alarm relay indication
MAIN FEATURES
• No external settings required
• Mutli-voltage operation: 220-480 VAC
50/60 Hz
• Operational current: 55/70/95 AAC
• Internally supplied
3-phase scroll
compressor soft starters
RSBD / RSBT Modbus
• Modbus RTU over RS485 serial
communication
• User settable device address: 1 - 247
• Enhanced current reduction capability
with patented auto-adaptive algorithm.
• cULus
MAIN FEATURES
• Communication of instantaneous
variables (current, voltage, kWh, power
factor)
• Remote start/stop via Modbus
• Alarm discrimination for quicker fault
diagnosis
3-phase scroll
compressor soft starters
RSDR
• Motor Rating: Up to 280 kW @400 V
• Ramp up time: 0.5 - 30 sec
• Internally bypassed
• 6-wire connection capability
• UL approved
MAIN FEATURES
• Multi voltage operation: 230 - 460
VAC, 50/60 Hz
• Auxiliary relays for run signal and
alarms
3-phase 280 kW
soft starters
RSGD 45mm
• Operational voltage range: 187 - 440
VAC, 187 - 660 VAC
• Operational current range: 12 AAC up
to 45 AAC
• Control voltage : 24 VAC/DC, 110 -
400 VAC
• Auxiliary relays for top of ramp and
alarms
• cULus, CCC
MAIN FEATURES
• Compact dimensions: up to 22 kW in
45 mm wide housing
• Easy to setup: standard 3-knob setting
• Internally bypassed and supplied
22 kW compact motor
soft starters
1,2,3,4,5,6 8,9,10
Powered by FlippingBook